For more guidance, like how to troubleshoot your boiler, read on! Check and correct damper motor end switch wiring. Additional Actions: The Genisys Primary Control may lock out for: For more possible causes, see the “Troubleshooting an Oil Burner” tech bulletin. Clock firing rate and adjust gas pressure regulator for higher pressure. This understanding is important to properly troubleshoot hot water boiler problems, which may occur as a result of an issue with an expansion tank. Grayfurnaceman Furnace Troubleshoot and Repair This site is dedicated to understanding the design, installation and repair of all types of furnaces, old or new. So how do you do this? They are caused by changes in fuel properties (utilities change gas properties in response to available supplies and outdoor temperature), air density changes (barometric pressure, temperature, moisture content), and boiler draft changes (outdoor temperature and wind conditions). If O2 (CO2) changes exceed 1% look for mechanical problems with fuel pressure regulation, draft control, or the burner’s blower and damper systems. All people in the building should exit it. Check and correct POC switch, adjustment and wiring. Check and correct fuel supply, air damper settings, blower wheel and motor, furnace draft. Generally, heat supply should be introduced gradually. At this point, you’ll need to troubleshoot or call a professional. This article was co-authored by our trained team of editors and researchers who validated it for accuracy and comprehensiveness. 120v is present at (L1 to L2) and (Limit to L2) of the Genisys Primary Control. This article was co-authored by our trained team of editors and researchers who validated it for accuracy and comprehensiveness. Also verify there is 120v at L1 to L2 and Limit to L2. Reddish blue flames could indicate higher than normal firing rate, or normal firing in a refractory lined chamber. Check and correct electrical power supply, re-set flame safeguard. To start a boiler, first make sure that you closely follow the safety procedures in your instruction manual for a safe start up. References. This guide is for Oil Burners using a GeniSys Control. It is recommended that, when possible, a continuous oxygen meter be installed in the feedwater system to detect oxygen intrusions. If less O2 (more CO2), check and correct:  adequate air supply to boiler room, boiler furnace pressure, firing rate (preferably by clocking a meter, but also compare to data in burner manual), calibration of analyzer, burner head selection and setting. Should you smell gas, don’t turn on anything (including phones or light switches), evacuate the building, and call the gas company for instructions. Always use properly calibrated instruments to set combustion. Boiler vs Furnace - Understanding Efficiency Ratings. The basic wiring schematics are located in the appropriate burner’s manual. When the limit string is complete, 120v is sent from terminal 5 of the controller subbase to the blower motor. Pronounced trumpet – treat as rumble or roar. When the reset light goes out, release the button. {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/1\/10\/Start-a-Boiler-Step-1.jpg\/v4-460px-Start-a-Boiler-Step-1.jpg","bigUrl":"\/images\/thumb\/1\/10\/Start-a-Boiler-Step-1.jpg\/aid8744318-v4-728px-Start-a-Boiler-Step-1.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"

License: Creative Commons<\/a>
\n<\/p>


\n<\/p><\/div>"}, {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/f\/f1\/Start-a-Boiler-Step-2.jpg\/v4-460px-Start-a-Boiler-Step-2.jpg","bigUrl":"\/images\/thumb\/f\/f1\/Start-a-Boiler-Step-2.jpg\/aid8744318-v4-728px-Start-a-Boiler-Step-2.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"

License: Creative Commons<\/a>
\n<\/p>


\n<\/p><\/div>"}, {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/2\/24\/Start-a-Boiler-Step-3.jpg\/v4-460px-Start-a-Boiler-Step-3.jpg","bigUrl":"\/images\/thumb\/2\/24\/Start-a-Boiler-Step-3.jpg\/aid8744318-v4-728px-Start-a-Boiler-Step-3.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"

License: Creative Commons<\/a>
\n<\/p>


\n<\/p><\/div>"}, {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/6\/6a\/Start-a-Boiler-Step-4.jpg\/v4-460px-Start-a-Boiler-Step-4.jpg","bigUrl":"\/images\/thumb\/6\/6a\/Start-a-Boiler-Step-4.jpg\/aid8744318-v4-728px-Start-a-Boiler-Step-4.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"

License: Creative Commons<\/a>
\n<\/p>


\n<\/p><\/div>"}, {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/d\/d3\/Start-a-Boiler-Step-5.jpg\/v4-460px-Start-a-Boiler-Step-5.jpg","bigUrl":"\/images\/thumb\/d\/d3\/Start-a-Boiler-Step-5.jpg\/aid8744318-v4-728px-Start-a-Boiler-Step-5.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"

License: Creative Commons<\/a>
\n<\/p>


\n<\/p><\/div>"}, {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/3\/33\/Start-a-Boiler-Step-6.jpg\/v4-460px-Start-a-Boiler-Step-6.jpg","bigUrl":"\/images\/thumb\/3\/33\/Start-a-Boiler-Step-6.jpg\/aid8744318-v4-728px-Start-a-Boiler-Step-6.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"

License: Creative Commons<\/a>
\n<\/p>


\n<\/p><\/div>"}, {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/5\/51\/Start-a-Boiler-Step-7.jpg\/v4-460px-Start-a-Boiler-Step-7.jpg","bigUrl":"\/images\/thumb\/5\/51\/Start-a-Boiler-Step-7.jpg\/aid8744318-v4-728px-Start-a-Boiler-Step-7.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"

License: Creative Commons<\/a>
\n<\/p>


\n<\/p><\/div>"}, {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/b\/ba\/Start-a-Boiler-Step-8.jpg\/v4-460px-Start-a-Boiler-Step-8.jpg","bigUrl":"\/images\/thumb\/b\/ba\/Start-a-Boiler-Step-8.jpg\/aid8744318-v4-728px-Start-a-Boiler-Step-8.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"

License: Creative Commons<\/a>
\n<\/p>


\n<\/p><\/div>"}, {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/d\/d9\/Start-a-Boiler-Step-9.jpg\/v4-460px-Start-a-Boiler-Step-9.jpg","bigUrl":"\/images\/thumb\/d\/d9\/Start-a-Boiler-Step-9.jpg\/aid8744318-v4-728px-Start-a-Boiler-Step-9.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"

License: Creative Commons<\/a>
\n<\/p>


\n<\/p><\/div>"}, {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/7\/7f\/Start-a-Boiler-Step-10.jpg\/v4-460px-Start-a-Boiler-Step-10.jpg","bigUrl":"\/images\/thumb\/7\/7f\/Start-a-Boiler-Step-10.jpg\/aid8744318-v4-728px-Start-a-Boiler-Step-10.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"

License: Creative Commons<\/a>
\n<\/p>


\n<\/p><\/div>"}, {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/a\/a6\/Start-a-Boiler-Step-11.jpg\/v4-460px-Start-a-Boiler-Step-11.jpg","bigUrl":"\/images\/thumb\/a\/a6\/Start-a-Boiler-Step-11.jpg\/aid8744318-v4-728px-Start-a-Boiler-Step-11.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"

License: Creative Commons<\/a>
\n<\/p>


\n<\/p><\/div>"}, {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/b\/b8\/Start-a-Boiler-Step-12.jpg\/v4-460px-Start-a-Boiler-Step-12.jpg","bigUrl":"\/images\/thumb\/b\/b8\/Start-a-Boiler-Step-12.jpg\/aid8744318-v4-728px-Start-a-Boiler-Step-12.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"

License: Creative Commons<\/a>
\n<\/p>


\n<\/p><\/div>"}, {"smallUrl":"https:\/\/www.wikihow.com\/images\/thumb\/e\/eb\/Start-a-Boiler-Step-13.jpg\/v4-460px-Start-a-Boiler-Step-13.jpg","bigUrl":"\/images\/thumb\/e\/eb\/Start-a-Boiler-Step-13.jpg\/aid8744318-v4-728px-Start-a-Boiler-Step-13.jpg","smallWidth":460,"smallHeight":345,"bigWidth":728,"bigHeight":546,"licensing":"

License: Creative Commons<\/a>
\n<\/p>


\n<\/p><\/div>"}. Replace purge card, re-set flame safeguard. Whole Latte Love has been serving the home espresso community for more than 20 years. Burner runs at low fire rate and air damper goes to high fire position but fuel valves will not go to high fire position (low/high/low control). Full opening of burner’s air shutter and band. wikiHow's Content Management Team carefully monitors the work from our editorial staff to ensure that each article is backed by trusted research and meets our high quality standards. By using our site, you agree to our. Additional Action: If the light remains on: See the Cad Cell Tech Bulletin for more information. But with the arrival of COVID-19, the stakes are higher than ever. http://www.weil-mclain.com/sites/default/files/field-file/cgm-pcg-series-4-manual_1.pdf, http://www.pvi.com/pdf%20files/Installation%20and%20Maintenance%20Manuals/19.pdf, http://pages.qualichem.com/blog/8-steps-to-a-proper-boiler-startup-procedure, Please consider supporting our work with a contribution to wikiHow. Examples are: Resistors JR1, JR2 and JR3. Domestic Hot Water Heating. Water from the boiler … Additionally, one of the first things to check on a hot water boiler system when the pressure relief valve discharges water excessively is the expansion tank. If your boiler doesn’t have this feature, follow the lighting instructions in your boiler’s user manual. Thanks to our Web-based control platform and available EMS monitoring service, you can exercise control, modify settings, troubleshoot malfunctions, and view graphs and data charts of stats and runtimes – from any device, anytime. Check and correct damper travel is unobstructed, damper motor end switch setting, wiring. When an HVAC (heating, ventilation, air conditioning) system doesn't work as it should, it can often be traced to a problem with the thermostat.This can actually be fortunate because problems with a thermostat are generally easier to fix than problems with the furnace or AC unit. Ignite your boiler by accessing its controls behind the front jacket panel and gradually heating it up. Burner runs, then stops and locks out during postpurge (RM7840L) (alarm light on). Turn the power off to the burner. Boilers should not pulse or make a hammering noise. Is jumper JR3 of RM7840L clipped? The burner manual has a section devoted to modulation adjustments – work from it. The water supply of boilers will collect foreign matter over time, like grease, oil, and more. When evaluating what is the difference between boiler and furnace, and which is better for you, the boiler furnace decision is just one of the decisions you’ll need to make. Refer to the Appliance manufacturer for recommended draft settings. Check and correct power supply to burner. The water level is low: Maintain the water level in the boiler at half-full.The boiler's automatic filling system, controlled by the pressure-reducing valve, should maintain the proper water level at 12 to 15 psi of pressure. Refer to the Oil Quality Tech Bulletin for more information. Check and correct: Draft is too high (tall stack, inadequate draft controls), lightoff rate is too high (check manifold pressure at light-off), ignition electrodes are worn or incorrectly set, incorrect burner head and/or head setting, high excess air, incorrect application (furnace too small), “feedback” resonance from stack (add a barometric). If so check and correct: Is control RM7840L (or RM7897 with jumper JR3 clipped)? Check your incoming voltage to L1 and L2. Pump Prime mode or the pump prime light is on inadvertently. Action: Verify: There is a call for heat. This will reset the control. In these instances, turn off power to the boiler, shut off its gas, and consult a professional. Some boilers may have more than one thermostat, like those that have both an operating thermostat and an upper operating thermostat. By forging relationships with our customers and manufacturers that are based on trust and a commitment to quality, we strive to be the best place to purchase coffee and espresso equipment on the Internet. Combustion Air Requirements Tech Bulletin. Check nozzle, draft and combustion chamber. Improper CO2 as recommended by the appliance manufacturer, Check the appliance manual for recommended CO2. Ignite your boiler by accessing its controls behind the front jacket panel and gradually heating it up. Include your email address to get a message when this question is answered. A Note About Efficiency. The pump prime light will turn on solid once the button is held for 15 seconds until the button is released. Normal condition for all of our “step spud” burners (all models offer this design). 3. Basing boiler output on outdoor temperature alone just isn’t accurate. Check and correct:  excess air is low (low O2 or high CO2), rate is high, operation at high elevation (flame expands in low barometric pressure), flue gas recirculation, cold furnace. Put a post purge on control to remove excess heat. Is JR3 intact? Observe the furnace for flame. For more information about the Low Firing Rate Baffle (click here). Draft is too high (tall stack, inadequate draft controls), Excess air too high, head setting, gas spud obstruction, supply pressure to gas train (high or very low pressure drop across regulator). ), breech damper too far closed, high boiler draft loss (incorrect spinners / turbulators / baffles, dirty boiler), flue gas analysis (high O2?). Changes of about 1% O2 (0.5% CO2) are normal. What’s So Special About Whole Latte Love?. Blower wheel not tight on motor shaft, correct blower wheel adjustment. To help troubleshoot the GeniSys control more effectively, use our Contractor’s Tool (Part number 52082U). Check high fire fuel pressure regulator setting – if it’s correct replace the high fire fuel valve. Trace power through rate control wiring to determine where power is lost – flame safeguard terminal – burner low fire switch – boiler rate control switch(es) – low air relay –  correct as required to power damper motor. This video explains how to troubleshoot the over temperature limit that shuts down the burner if the temperature inside the ductwork is too high. Always operate and maintain your boiler as directed in its user manual. Please consider supporting our work with a contribution to wikiHow. Refer to our Commercial Gas Specification Guide to see start up settings. Specified damper opening is a guideline for start-up, don’t be afraid to change it. Run a vacuum test, Use a clear hose on the pump bleeder port to see if there is air present. Check for warpage or damage to blower wheel. Large additions require a separate boiler or other sources of heat. The control will reset. For more guidance, like how to troubleshoot your boiler, read on! Unless your boiler has a clearly indicated manual lighting procedure, you should not attempt to manually light your boiler. Observe the furnace for flame. The boiler, for the espresso shot, is PID temperature controlled, while a separate steam boiler offers instant and powerful steam on demand. Hold the reset button down for 15 seconds. Bleed the oil pump. Notes: The pump prime light will turn on solid once the button is held for 15 seconds until the button is released. Check and correct ignition and fuel valve wiring, re-set flame safeguard. If voltage is present: Is jumper JR3 of RM7897 clipped? Refer to your GeniSys manual for more information. Check and correct flame sensing circuit (cad cell and wiring). If your boiler fails to start, reset the thermostat to the lowest temperature, turn off power to the boiler, and turn off the gas. Refer to the Nozzle Afterdrip Tech Bulletin for more information. Improper boiler startup or operation could result in damage to the boiler, exposure to hazardous materials, fires, or an explosion. To help troubleshoot the GeniSys control more effectively, use our Contractor’s Tool (Part number 52082U). The flame light should go out on the Primary Control. Cause 4 – O2 (CO2) – outside specified range during modulation. If not, burner would not have locked out. Thanks to all authors for creating a page that has been read 39,957 times. If not, burner would not have locked out. I am a retired HVAC serviceman and instructor. Check and correct: wheel set screw tightness, wheel-to-motor plate and wheel-to-inlet guide clearances, wheel integrity. When you buy a refurbished espresso machine from Whole Latte Love, you're getting it in like-new condition at the best price, with unlimited customer support. If noise persists, put on a vacuum gauge at the fuel pump’s inlet to see if there is a restriction in the oil supply line. Both iron and copper, as well as oxygen, can be measured on a daily basis. Is jumper JR3 Intact? If not, turn the power back on and increase the thermostat by increments of less than 100°F every hour until you reach your target temperature. If not, burner would not have locked out. Verify the cad cell is not seeing any apparent light. Wait until the boiler temperature reaches the required level at which the pump should cut in, and then check the device. Press and hold the reset button for at least one second. This should be cleaned, a process called “skimming,” approximately once a year. Pre-set air settings are approximate for start-up. Central Boiler Outdoor Furnace Features. Notes: The GeniSys Primary Control may lock out for: The Genisys Primary Control is in a Restricted (hard) lockout This means the control has locked out 3 times. Boiler Treatment. Check burner head identification and orifice sizes. Troubleshoot your boiler by checking its connections, fuses, and the gas supply. This information should be indicated on the attached label directions or in the user manual. When the reset light goes out, release the button. Check and correct:  high draft (no barometric? 2. Unfortunately, problems can occur when you need your boiler most. We've been helping billions of people around the world continue to learn, adapt, grow, and thrive for over a decade. Burner has a whining noise while running. Hold the reset button down for 15 seconds. For additional potential causes (Click Here). Controlling the boiler based on the actual temperatures inside apartments is the only way to to prevent overheating (and wasted fuel), while keeping tenants comfortable and happy. It happens to all of us, from time to time, when our espresso machines start behaving differently. 120v is present at (L1 to L2) and (Limit to L2) of the GeniSys Primary Control. If you smell gas, do not turn on any appliances, light switches, or phones. Troubleshoot videos The video below begins the troubleshoot of the Goodman 80% furnace with an overview of common failures with this furnace. Call the fire department if you cannot contact your supplier. Press and hold the reset button for at least one second. Check and correct POC switch, adjustment and wiring. Check for air in the fuel supply line. So you can extract your shot at the right temperature, delivering optimal flavor, while simultaneously steaming your milk to cafe quality. We use cookies to ensure that we give you the best experience on our website. If so, check and correct: Is the control RM7840L or RM7897 with jumper JR2 clipped? ), breech damper too far open, low boiler draft loss (missing spinners / turbulators / baffles). This will reset the control. Specified damper opening is a guideline for start-up; don’t be afraid to change it. % of people told us that this article helped them. Blocked flue, heat exchanger and chimney. Call your gas supplier from outside or a neighbor’s phone to receive further instructions. If the burner starts, then check your thermostat. The boiler doesn't have power: The circuit breaker or fuse controlling the furnace may have tripped or blown. The photo at page top shows a modern Extrol(R) bladder-type heating system expansion tank. Verify there are not any exposed wires. Refer to the appliance manual for recommended set-up procedure. 120v is present at (L1 to L2) and (Limit to L2) of the Genisys Primary Control. If more O2 (less CO2), check and correct:  stack draft (barometric control is recommended for stacks over 10′ tall), firing rate (preferably by clocking a meter, but also compare to data in burner manual), calibration of analyzer, burner head selection and setting. You can revoke your consent any time using the Revoke consent button. Check and correct:  burner head not centered in air tube, gas orifice obstructed, furnace flow pattern (flame drawn toward furnace outlet), furnace refractory pattern (re-radiated heat from refractory speeds up flame), flame buoyancy in furnace (greater influence in cold furnace). pressure fluctuations coming to gas train from oversized supply regulator, pressure fluctuations coming to furnace from flue stack (add a barometric), un-approved boiler application (furnace too small).